12 Propane Convection Heater Manual
THEORY OF OPERATION
Fuel Supply System Fuel is supplied under pressure from the fuel cylinder to the heater by the hose/
regulator assembly. The regulator maintains a constant ow of fuel to the heater.
System of Ignition As the fuel is sprayed into the combustion chamber, through a supply nozzle, the
Piezo ignitor ignites the ne mixture of fuel and air.
Automatic Control System If the ame should extinguish, the Automatic Control Valve shuts down the
heater.
WARNING: REVIEW AND UNDERSTAND ALL OF THE WARNINGS IN THE SAFETY INFORMATION
SECTION OF THIS MANUAL.
WARNING: DUE TO VERY HIGH SURFACE TEMPERATURES, IT IS IMPORTANT TO KEEP
CHILDREN, FURNITURE AND CLOTHING AWAY FROM THE HEATER. KEEP CONTROL AND
BURNER AREA FREE FROM DIRT AND DEBRIS.
WARNING: EXTREMELY HOT WHILE IN OPERATION. DO NOT TOUCH HEATER WHILE
OPERATING. KEEP CHILDREN, FURNITURE, CLOTHING, GASOLINE AND OTHER FLAMMABLE
LIQUIDS AND VAPORS AWAY FROM HEATER.
NOTE: Once the gas connection has been made, air may be trapped in the gas line. Before lighting the heater it will be neces-
sary to purge any air trapped in the line. Once this is done the heater will light and operate normally. Purging the gas line
will be necessary every time the gas cylinder is replaced.
PREPARING FOR OPERATION
1. Check the heater for possible shipping damage. If any is found, immediately notify your local dealer.
2. Follow all Safety Information in this manual.
LIGHTING INSTRUCTIONS (MH-0080-CM10)
1. Stop! Read all of the Safety Information provided with this heater
2. Turn valve on propane cylinder counterclockwise until fully open
3. Press in Control Knob and turn counterclockwise to LOW/IGN position
4. If burner does not ignite, turn Control Knob to OFF position and repeat the ignition procedure
5. Keep Control Knob pressed in for approximately 15 seconds before releasing.
6. If the ame goes out, wait 5 minutes, and repeat the ignition and lighting steps
7. After heater ignites, turn Control Knob to desired heat setting.
RELIGHTING INSTRUCTIONS
1. Rotate valve on cylinder clockwise to close it, and wait ve (5) minutes.
2. Relight following the LIGHTING INSTRUCTIONS.
SHUT-DOWN INSTRUCTIONS
1. Turn Control Knob to the OFF position
2. Rotate valve on cylinder clockwise to close it
LIGHTING INSTRUCTIONS (MH-0200-CM10)
WARNING: BEFORE LIGHTING HEATER, TURN MAIN BURNER VALVE TO LIGHT POSITION. READ
SAFETY WARNING: INFORMATION BEFORE STARTING THE HEATER.
1. Fully open the valve on the propane tank, and set burner valve to LIGHT position, then wait 15 seconds
before Step 2.
2. Depress the red button on the safety shut-off valve, admitting gas to the burner. Then push and release the
ignition button until the burner lights.