12  WP-Cold Water Direct Driven Operator’s Manual
WATER SUPPLY:
1.  Select a watersupplyhosewhich is aquality gradeofgardenhosemeasuring 
at least 3/4” ID and no longer than 50 feet.
2  Checkthe water inlet strainerto ensureitis clean and freeof any obstructions. 
Periodic cleaning of the water strainer will help prevent pump problems. As 
a strainer becomes obstructed, it restricts proper ow of water to the pump.
This can result in cavitations which will cause premature failure of pump 
packings.  
a.  Using a screw driver, remove the screen from the water inlet.
b.  Clean or replace with Mi-T-M
®
 #19-0001 if necessary.
 3.  Connect the hoses.
a.  Connect one end  of  the water  supply  hose to the  water  inlet of the 
unit.  
b.  Connect the other end of the hose to your pressurized water supply.
NOTE: Do not use a non-pressurized water supply (i.e. from a pond or well)
with this unit.
c.  Connect the high pressure discharge hose to the water outlet of the 
unit. 
d.  Securely connect the other end of the hose to the gun assembly. (A
wrench may be required on some models.)
e.  Connect the wand assembly to the gun/hose assembly.
4.  Follow the incoming water requirements listed below:
a.  Water pressure must be a minimum of 25 pounds per square inch (PSI) 
and a maximum of 125 PSI. (Atypical outdoor faucet will generally 
supply this PSI if turned completely “ON”.) 
b.  Incoming GPM  must be  approximately one  gallon more  than the 
outgoing GPM stated on the pressure washer nameplate. (You can 
check GPM by timing how long it takes to ll a 5 gallon container.)
c.  Incoming water temperature must not exceed 125°F.  Excessive pump 
damage may result if the water temperature exceeds this acceptable 
level.
5.  Never allow the unit to operate without theincoming water line attached and 
the water supply completely turned on.
CHECK WATER INLET STRAINER
INSTALLATION & PREPARATION
UNLOADER:
THE UNLOADER WILL EITHER BE ADJUSTABLE OR FACTORY PRESET
DEPENDING ON THE MODEL YOU PURCHASED.
ADJUSTABLE:
The unloader  valve  on your  machine is equipped  with an  adjustment knob 
to  adjust  the  pressure.  Should less  pressure  be  required,  simply  turn the 
adjustment knob counterclockwise.  To set back to maximum, turn adjustment 
knob completely clockwise.  DO NOT OVERTIGHTEN!
FACTORY PRESET:
The  unloader  valve on  your machine  is factory preset  and should only be 
adjusted by a trained Mi-T-M Representative. DO NOT adjust the pressure on 
your own!
CAUTION
RISK OF UNIT DAMAGE!
DO NOT OVERTIGHTEN THE
UNLOADER. BREAKAGE COULD
RESULT IN IMMEDIATE LOSS OF
WATER PRESSURE AND COSTLY
REPAIRS.
Adjustable Factory Preset