Mi-T-M® CORPORATION, 8650 Enterprise Drive, Peosta, IA 52068 Tel: (800) 553-9053 Fax: (563) 556-1235 e-mail: [email protected] Website: http://www
10SPECIFICATIONS, FEATURES & OPTIONSElectric Model Specifications*Output temperatures are based on an input temperature of 55 deg. FNOTES:1. Stand
11ELECTRICAL CONTROL PANEL
12EH-2303-0M30 SCHEMATIC
13EH-3004-0M30 SCHEMATIC
14ELECTRICALLY HEATED PARTS BREAKDOWNITEM NO. PART NO. DESCRIPTION 1 EP: 24751 Cover 2 EP: 24757 frame panels 3 FA: 315-006 rubber feet 4
15ELECTRICALLY HEATED PARTS BREAKDOWNITEM NO. PART NO. DESCRIPTION 41 EL: 45DG10AJ reset contactor & flow switch contactor 42 EL: S1210 mot
16UNLOADER VALVEUVP 1060 ITEM DESCRIPTION PART NUMBER 1 Inlet Fitting 60.0024.31 2 O Ring 10.3068.00 3 Ball spring 60.0015.51 4 S.
17UNLOADER - MTMPart # Code Description No.1 OT354127
18GENERAL PUMP TS1331 ITEM DESCRIPTION PART # QTY INCLUDED IN KIT 1 Pump Head 47.1208.41 1 2 Screws 99.3206.00 8 3
19GENERAL PUMP T2011 ITEM DESCRIPTION PART # QTY INCLUDED IN KIT 1 Pump Head 47.1209.41 1 2 Screws 99.3206.00 8 3 Was
2TABLE OF CONTENTSImportant Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Pre-Operating Instructions
20TROUBLE POSSIBLE CAUSE REMEDY Low Pressure Loose belt on pump Tighten pump Leaks in water system Tighten all fittings Insufficient water supp
21MI-T-M® WARRANTYWarranty does not include damage from negligence, abuse or freezing and is limited to the repair or replacement of the part(s). War
22
31. Read all safety and operating instructions before using the unit.2. Read all electrical hook up instructions.3. Read warnings on additive conta
4 When unpacking the unit, if you find damage due to shipping, contact your dealer or Mi-T-M Corporation immediately,ELECTRICAL SUPPLYArrange with an
5 When unpacking the unit, if you find damage due to shipping, contact your dealer or Mi-T-M Corporation immediately,HOT PRESSURE WASHER MODE (P Units
6 HOT PRESSURE WASHER MODE (PS Units only)SET-UP PROCEDURE:1. Connect water supply to inlet on back of unit (minimum pressure 15 psi and maximum inlet
7SAFETY COMPONENTSFLOW SWITCHThe flow switch prevents the burner from being turned on if there is insufficient water. Proper water flow causes the ma
8THINGS TO CHECK REGULARLY1. Check for SYSTEMS LEAKS. Leaks in the pressure side of the system can cause premature wear (or even failure) of
9SERVICE AND MAINTENANCEBefore carrying out maintenance work or repairs, disconnect the plug from the power supply.MAINTENANCE SCHEDULE:WEEKLY:Check t